Fire Alarm
Showing 16–25 of 25 results
-
Addressable Systems, Fire Alarm, Security Systems
OMS 3301
OUTPUT MODULE FOR SIGNALING DEVICES 1X
Intelligent Input/Output module for the Loop 3000 for the control of external optical and acoustic signaling devices with bidirectional isolator according to EN 54-17 and EN 54-18. Including one monitored fault input and one potential free relay output for signaling devices.
Highlights
- Integrated automatic switch function of the output at “external signal line on/off” signal by the fire control panel
- Connecting module with one freely programmable fault input and one output for the connection of signalling devices
- Programming of different switching variants of input and output also with time control
- Monitoring of the operating status via Loop 3000
- Independent programming of input and output
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Multi-color LED for alarm (red) and fault (yellow)
- Robust wall-mounted housing according with IP 54
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3200 O
OPTICAL SMOKE DETECTOR WITHOUT ISOLATOR
Optical smoke detector for Loop 3000 with two optical sensors for earliest fire detection and indication according to EN 54-7
Highlights
- Pollution detection of the smoke measurement chamber by an additional optical path
- Detector sensitivities are automatically adapted and programmable
- Fault monitoring of the measurement chamber signal and Loop 3000 electronics
- Periodic sensor test
- Automatic and manual addressing with Loop 3000
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including protective cover for the installation phase
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 MCP
MANUAL CALL POINT
Manual Call Point for loop3000 for the manual activation of an alarm with bidirectional isolator according to EN 54-11: A1, EN 54-17. Red plastic housing with imprint “burning house”.
Highlights
- Manual Call Point mechanics for the activation of a manual alarm
- Non-destructive activation and reset via mechanics
- Automatic and manual addressing with Loop 3000
- Integrated Isolator with T-branch
- Functions completely integrated via Loop 3000-protocol
- Integrated red Alarm-LED
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 OTi
INTELLIGENT MULTI-SENSOR DETECTOR WITH ISOLATOR
Intelligent optical and thermal multi-sensor detector for loop3000 with two optical and two thermal sensors and a bidirectional isolator for earliest fire detection and indication in all environments with difficult ambient conditions, according to EN 54-5/-7 /-17, prEN 54-29 and CEA 4021. Fusion® technology for the detection of the smallest smoke particles and fires in the early stage by using the wavelengths of the wide-band white light spectrum.
Highlights
- Individual use of the thermal measurement according to EN 54-5 in the sensitivity levels 2 to 5 as maximum detector (static –> A1S, A2S) or as rate-of-rise detector with a maximum threshold (differential and static –> A1R, A2R)
- Individual change of detector class for sensitivity levels 2 to 5 using Easy Check 3000
- Pollution detection of the smoke measurement chamber by an additional optical path
- Detector sensitivities are automatically adapted and programmable
- Integrated measurement system and algorithm for condensation recognition (Humitec®)
- Intelligent analysis and suppression mode for the elimination of false alarms (e.g. cigarette smoke)
- Highest reliability by optimal adjustment of the alarm threshold via intelligent algorithm for the fire detection
- Fault monitoring of the measurement chamber signal and Loop 3000 electronics
- Periodic sensor test
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including dust protection cover for installation phases
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 PBDH ABS R
MANUAL CALL POINT, RED
Manual Call Point for Loop 3000 for the manual activation of an alarm with bidirectional Isolator and status display via LED according to EN 54-11.
Highlights
- Push Button mechanics for the activation of a manual alarm
- Activation after smash of the front glass
- Integrated reset mechanics
- Automatic and manual addressing with Loop 3000
- Integrated Isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Integrated red LED for Alarm
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 S 1 SE
CONUS – LOOP SOUNDER – RED
Intelligent acoustic signaling device for the Loop 3000 for the external acoustic alarm with bidirectional isolator according to EN 54-3 and EN 54-17.
Highlights
• Activation, monitoring, and supply via Loop 3000-protocol
• Integrated automatic reset function at signal “external signal line on/off” by the fire control panel
• Monitoring of the operating status via Loop 3000
• Independent programming via loop address
• Automatic and manual addressing with Loop 3000
• Integrated Isolator
• 28 different tones, adjustable via DIP-switch including DIN-signal
• Loudness adjustable via DIP-switch
• Functions completely integrated via Loop 3000-protocol
• An aesthetical, robust wall-mounted housing according to IP 41
• Integrated detector base of the PL 3000 seriesSKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 T
THERMAL DETECTOR WITH ISOLATOR
Thermal detector with fixed and rate of rising temperature settings for Loop 3000 with two thermal sensors for earliest fire detection and indication in all environments with difficult ambient conditions and with bidirectional isolator, according to EN 54-5 and EN 54-17
Highlights
- Thermal detector, certified according to EN 54-5 in the temperature classes A1R, A1S (A1) and A2R, A2S (A2), and EN 54-17
- Individual use of the thermal measurement according to EN 54-5 in the sensitivity levels 2 to 5 as maximum detector (static –> A1S, A2S) or as rate-of-rise detector with a maximum threshold (differential and static –> A1R, A2R)
- Individual change of detector class for sensitivity levels 2 to 5 using Easy Check 3000
- Periodic sensor test
- Automatic and manual addressing with Loop 3000
- Integrated Isolator and T-branch option
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including protective cover for the installation phase
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
SDB 3000 S
DETECTOR BASE CT 3000 S
Detector base for all detectors of series CT 3000 and Loop 3000
Highlights
- Integrated connectors for LED indicator (Art.-No.31193) or piezo buzzer Art.-No. 32091
- Space for additional connectors Type WAGO 243
- Integrated terminals for connection of a branch as loop expansion (T-Junction)
- Mounting space for the piezo buzzer (Art.-No. 32091) and the detector labeling clip Art-No. 30479
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
SDB 3000 S
DETECTOR BASE CT 3000 S
Detector base for all detectors of series CT 3000 and Loop 3000
Highlights
- Integrated connectors for LED indicator (Art.-No.31193) or piezo buzzer Art.-No. 32091
- Space for additional connectors Type WAGO 243
- Integrated terminals for connection of a branch as loop expansion (T-Junction)
- Mounting space for the piezo buzzer (Art.-No. 32091) and the detector labeling clip Art-No. 30479
SKU: n/a