Addressable Systems
Showing 1–15 of 35 results
-
Door Phones, SIP Video Intercom
C312A
The Akuvox C312A is a cost-effective audio-only door intercom device for use as part of a remote communication and door entry system.Featuring Wifi and Bluetooth for wireless LAN and third party device connectivity, this discreet and stylish intercom panel is designed for indoor use as part of a door entry / access system in conjunction with other IP intercom devices from the Akuvox product range.The Akuvox C312A allows 2-way audio communication between residents and visitors before allowing access to the building. If the user is happy to allow the visitor in, they can remotely unlock internal/external doors or gates (using IP{-addressable remote door locks), making these simple-to-use intercom devices ideal for MDU / apartment projects, large homes or office buildings.This device is designed for indoor use only and can be wall-mounted using the supplied magnetic mounting bracket.-
Stylish door entry / communication intercom system
-
IP addressable for use with Akuvox range of IP Intercom products
-
Audio-only device (no video)
-
High definition audio communication
-
Remote door unlocking
-
Receive audio from connected indoor / outdoor access / intercom terminals
-
Two-way communication with other C312 Panels or IP Telephone devices on the network
-
Easily integrates with SIP Systems
-
Power supply via PoE or adapter
-
Stylish, elegant design
-
Black or White Colour Option
SKU: n/a -
-
Addressable Systems, Fire Alarm, Security Systems
CP 3500 LOM P
LOOP MODULE FOR FIRE CONTROL PANEL DC3500, PROTECTED Microprocessor-controlled loop interface for dc3500 with special coating against condensing water for uninterruptible and short-circuit-proof use with 126 Loop 3000 fire detection system components.
Highlights
- Connection of Loop 3000 components in loop structure or spur-structure
- 2-wire-system loop with up to 3.500 m loop length
- Easy and flexible installation and initialization via automatic and manual addressing
- System plug to connect to dc3500 system
- System socket to connect additional modules to the dc3500 system
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
CS 200 R
SOUNDER – RED 112 DB
Acoustic multiple-tone sounder for an external acoustic alarm according to EN 54-3
Highlights
- 32 different tones via DIP-switch, including DIN-tone
- Automatic synchronization
- Integrated two-tone alarm function
- Flat design
- Internal volume adjustment
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
CT 3000 OT
MULTI-SENSOR DETECTOR, CONVENTIONAL
Optical and thermal multi-sensor detector for conventional systems for earliest fire detection and indication in all environments with difficult ambient conditions according to EN 54-7 and EN 54-5 class A1
Highlights
- Integrated temperature measurement as the rate of the rising procedure and maximum value by EN 54-5
- Professional smoke detection system with the highest reliability for secure alarm verification with three-fold measurement
- Periodic sensor test
- Alarm output to control parallel indicator
- LED for alarm (red)
- Integrated locking system for protection against removal and tampering
- Delivery including protective cover for the installation phase
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
CT 3000 PBDH ABSR
MANUAL CALL POINT, RED
Manual Call Point for conventional systems for the manual activation of an alarm and status display via LED according to EN 54-11
Highlights
- Push Button mechanics for the activation of a manual alarm
- Integrated reset mechanics (operation from inside)
- LED for alarm (red)
- Encapsulated plastic housing
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
CT 3000 T
THERMAL DETETOR, CONVENTIONAL
Heat detector with fixed and rate of rising temperature settings for conventional systems for earliest fire detection and indication in all environments with difficult ambient conditions according to EN 54-5 class A1.
Highlights
- Integrated temperature measurement as the rate of the rising procedure and maximum value by EN 54-5
- Periodic sensor test
- Alarm output to control parallel indicator
- LED for alarm (red)
- Integrated locking system for protection against removal and tampering
- Delivery including protective cover for the installation phase
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems, Uncategorized
DC 3004PLUS
FIRE CONTROL PANEL DC 3004PLUS, M-TYPE HOUSING, GB
Microprocessor-controlled fire control panel for use with the loop 3000 fire detection system components.
Highlights
- Large LCD, 160 x 80 points
- RS-232 interface for easy programming via DPT-Software
- Space for 2 modules to connect 2 x 126 loop 3000 fire detection system components per module
- Up to 128 programmable detector zones
- Event log memory of up to 500 messages
- Easy programming of up to 504 connections
- In accordance with EN 61000-6-3 class B for emissions, so suitable for use in sensitive areas
- Option for 2 conventional interface cards for controlling up to 16 conventional zones
- Extinguishing interface for controlling extinguishing and gas suppression systems in accordance with EN 12094
- Integrated interface for the connection of up to 63 additional network components
- Integrated control of extinguishing systems via the standard extinguishing interface in accordance with VdS
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
DC3500M
FIRE CONTROL PANEL DC3500 M
Compact microprocessor-controlled fire control panel for use with the Loop 3000 fire detection system components.
Highlights
- Clear display and easy operation via the color display with touchscreen
- USB-Interface for easy programming via DPT-Software
- Space for up to 15 modules to connect up to 126 Loop 3000 fire detection system components per module
- Programming of up to 1890 detector zones
- Event log memory for 100.000 messages
- Easy programming of up to 10.000 cause & effects
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
DCC4
FIRE CONTROL PANEL 4 ZONES, GB
Compact microprocessor-controlled fire control panel for use with the CT 3000 fire detection system components. Approved according to EN 54-2: 1997/A1: 2006 and EN 54-4: 1997/A2: 2006
Highlights
- Clear display and easy operation with LED displays and operation keys
- Connection possibility for 4 conventional zones for the use with the CT 3000 fire detection components with up to 20 detectors per zone
- An integrated power supply according to EN 54-4: 1997/A2: 2006 with 1 output for external devices rated at 24 V DC
- Independent connection of detector and signaling device zones
- Integrated “one-man-revision mode”
- Manual control of signaling devices via separate input
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
DCC8
FIRE CONTROL PANEL 8 ZONES, GB
Compact microprocessor-controlled fire control panel for use with the CT 3000 fire detection system components. Approved according to EN 54-2: 1997/A1: 2006 and EN 54-4: 1997/A2: 2006
Highlights
- Clear display and easy operation with LED displays and operation keys
- Connection possibility for 8 conventional zones for the use with the CT 3000 fire detection components with up to 20 detectors per zone
- Extension option via 4 zone modules for up to 16 conventional zones for CT 3000 fire detection components
- An integrated power supply according to EN 54-4:A2 2006
- Independent connection of detector and signaling device zones
- Integrated “one-man-revision mode”
- Manual control of signaling devices via separate input
- Programming options such as alarm delay
- Panel network of max. two fire control panels
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
DLI 3240 PS X1
2 LOOP INTERFACE, ACTIVE, 2 X 140 MA FOR DETECT 3004PLUS
Microprocessor-controlled loop interface for dc3004plus for uninterruptible and short-circuit-proof use with 2 x 126 Loop 3000 fire detection system components.
Highlights
• Connection of Loop 3000 components in loop structure or spur-structure
• 2-wire-system loop with up to 3.500 m loop length.
• Easy and flexible installation and initialization via automatic and manual addressing
• Integrated RS-232 interface for easy analysis of the loop components, the preadjustment of functions, and commissioning of Loop 3000
• 8 integrated freely programmable open-collector-alarm outputs
• 2 integrated open-collector-alarm outputs for the programming of collecting functions
• Commissioning and service tool for analyzing and fault-finding functions with I-Check softwareSKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
DMCL05
CONVENTIONAL MANUAL CALL POINT resettable with a key without breaking glass led and alarm resistor integrated, RED color, EN54-11, CE according to CPD
Highlights
- CE certified according to CPD
- Conform with the norm EN54-11
- Key for reset
- The separate key for test
- No broken glass
- Red color for Alarm status
- Yellow color for extinguishing command
- Blue color for Extinguishing abort
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
DSF 2000-RR
CONVENTIONAL sounder + flash (red flash + red box);
3 different sounds, 97dB, low current consumption, IP21C, EN54-3, EN54-23, CE according to CPD/CPR (exist also in white flash), base included
Highlights
- Ceiling: up to 3m height – 8 m diameter
- Wall: up to 2,4 m height- 4,2m
- depth/width
- Flash Red color
- IP21C
- Ceiling or wall mounting
- 3 different sounds
- 97 dB Sound Power@1m
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
IOM 3311
IN-/OUTPUT MODULE 1X
Intelligent Input/Output module for the Loop 3000 with bidirectional isolator according to EN 54-18 and EN 54-17. With one monitored input and one potential free relay output
Highlights
- Connecting module with one programmable input and one programmable output
- Programming of different s different switching variants of input and output rol for one detector group.
- Monitoring of the operating status via Loop 3000
- Independent programming of input and output
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Multicolour LED for alarm (red) and fault (yellow)
- A robust wall mounted housing according to IP 54
SKU: n/a