Security Systems
Showing 16–30 of 50 results
-
Access Control, Security Systems
EC33
Elevator Controller
Relay Output:32
Card Reader: Support wiegand 26/34
Storage: 20,000 cards & 100,000 logs
Expansion: Support to connect one expansion panel to reach 64 output
Communication: TCP/IP,RS485
Support working with Akuvox indoor monitor for remote elevator calling functionSKU: n/a -
Access Control, Security Systems
Face Pass 7
FacePass 7 flagship face recognition product launched by Anviz, based on a new infrared technology design, using the world’s leading BioNANO core algorithm, with a powerful processor and hardware computing platform, face detection, identification, and event real-time push can be easily implemented. It can realize accurate facial recognition in various environments.
Highlights
- Dual 1.0Ghz High-Speed Processor
- Dual Cameras
- 3,000 Users, 100,000 Records
- 3.2″ Touch Screen TFT LCD
- USB Host, TCP/IP, WIFI and Optional 4G
- Voice and LED Prompt
- Body Induction, Day/Night Switch
- Relay output Wiegand output,32 timezone and 16 groups
- Door Sensor and an Exit button
- Scheduled Bell, Tamper Alarm
- Inbuilt Webserver
- Standard EM RFID
- DC 12V
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
IOM 3311
IN-/OUTPUT MODULE 1X
Intelligent Input/Output module for the Loop 3000 with bidirectional isolator according to EN 54-18 and EN 54-17. With one monitored input and one potential free relay output
Highlights
- Connecting module with one programmable input and one programmable output
- Programming of different s different switching variants of input and output rol for one detector group.
- Monitoring of the operating status via Loop 3000
- Independent programming of input and output
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Multicolour LED for alarm (red) and fault (yellow)
- A robust wall mounted housing according to IP 54
SKU: n/a -
Access Control, Security Systems
M3PRO (Outdoor Metal RFID)
M3 Pro is a metal casing, IP65 water-proof access control device, It supports a 13.56MHZ Mifare card and 125KHZ EM card dual frequency RFID module. The touch backlit keypad gives the best user experience, M3 pro also supports TCP/IP and RS485 communication and web server function to realize easy self-management. The optional WIFI and Bluetooth function can realize flexible applications and near-field mobile phone magic shake opening. The easy cloud application is also compatible with M3 pro
Highlights
- 1GHZ High-Speed CPU, Stable and reliable.
- Keypad registration.
- Compact Design.
- 10,000 cards, 200,000 Records.
- Touch Backlight Keypad.
- TCP/IP, RS485.
- Tamper alarm USB Device.
- Direct Lock Control.
- Door Open Sensor.
- Wiegand Out.
- Card, PW, IP65, Standard EM card & Mifare Card
SKU: n/a -
Access Control, Security Systems
M5PRO
M5 Pro by ANVIZ is a compact access control device that is designed to fit most door frames. With IP65 water-proof design, the metal casing makes it suitable for indoor or outdoor applications. M5 Pro supports 125kHz Optional Mifare cards and fingerprint identification.
Highlights
- ST Microelectronics® 32-Bit High-Speed CPU.
- Stable and reliable.
- Management Card Registration.
- Compact Design.
- 5000 Fingerprints, 50000 Records.
- Auto Wakeup Sensor.
- Multiple communication modes such as TCP/IP, RS485, and Wiegand Out.
- Direct Lock Control.
- Tamper alarm output.
- FP, Card, IP65, Standard EM RFID.
Anviz_M5Pro_Catalogue_EN_07.16.2018
SKU: n/a -
Conventional Systems, Fire Alarm, Security Systems
OC05
CONVENTIONAL OPTICAL SMOKE DETECTOR, 1 remote led output, EN54-7 , CE according to CPD/CPR
Highlights
- Photoelectric scattering (Tyndall effect)
- 1 remote alarm indicator output
- Lockable
- Standard EN54-7
- Cable section max 2,5mm²
- 12V version
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
OMS 3301
OUTPUT MODULE FOR SIGNALING DEVICES 1X
Intelligent Input/Output module for the Loop 3000 for the control of external optical and acoustic signaling devices with bidirectional isolator according to EN 54-17 and EN 54-18. Including one monitored fault input and one potential free relay output for signaling devices.
Highlights
- Integrated automatic switch function of the output at “external signal line on/off” signal by the fire control panel
- Connecting module with one freely programmable fault input and one output for the connection of signalling devices
- Programming of different switching variants of input and output also with time control
- Monitoring of the operating status via Loop 3000
- Independent programming of input and output
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Functions completely integrated via Loop 3000-protocol
- Multi-color LED for alarm (red) and fault (yellow)
- Robust wall-mounted housing according with IP 54
SKU: n/a -
Security Systems, Time Attendance
P7 (POE, Touch Active)
P7 is a new generation access control device of Anviz. The P7 adopts touch activation technologies in the fingerprint sensor and keypad easy for user operation. An access control, designed with PoE communication and access interface separation, makes the P7 easy to Installation and costs down the labor. The powerful access control function is indispensable for P7. Relay output for door control, Wiegand output and group, time zones. Multi-communication with TCP/IP, RS485, and Mini USB port. The Alarm push function will protect access control safe.
Highlights
- ST Microelectronics® 32-Bit High-Speed CPU.
- Stable and reliable.
- 5000 Fingerprints, 50000 Records.
- Touch Active.
- Wakeup Sensor.
- Touch Backlight Keypad.
- Door Open Sensor.
- RS485, USB Device,TCP/IP(PoE),Wiegand In/Out.
- Direct Lock Control.
- Group, Time Zone, Scheduled Bell.
- Doorbell & Relay Out.
- Standard with EM card
- Tamper Alarm.
- FP, Card, ID+FP, ID+PW, PW+Card, FP+Card, FP+PW, and IP53
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3200 O
OPTICAL SMOKE DETECTOR WITHOUT ISOLATOR
Optical smoke detector for Loop 3000 with two optical sensors for earliest fire detection and indication according to EN 54-7
Highlights
- Pollution detection of the smoke measurement chamber by an additional optical path
- Detector sensitivities are automatically adapted and programmable
- Fault monitoring of the measurement chamber signal and Loop 3000 electronics
- Periodic sensor test
- Automatic and manual addressing with Loop 3000
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including protective cover for the installation phase
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 MCP
MANUAL CALL POINT
Manual Call Point for loop3000 for the manual activation of an alarm with bidirectional isolator according to EN 54-11: A1, EN 54-17. Red plastic housing with imprint “burning house”.
Highlights
- Manual Call Point mechanics for the activation of a manual alarm
- Non-destructive activation and reset via mechanics
- Automatic and manual addressing with Loop 3000
- Integrated Isolator with T-branch
- Functions completely integrated via Loop 3000-protocol
- Integrated red Alarm-LED
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 OTi
INTELLIGENT MULTI-SENSOR DETECTOR WITH ISOLATOR
Intelligent optical and thermal multi-sensor detector for loop3000 with two optical and two thermal sensors and a bidirectional isolator for earliest fire detection and indication in all environments with difficult ambient conditions, according to EN 54-5/-7 /-17, prEN 54-29 and CEA 4021. Fusion® technology for the detection of the smallest smoke particles and fires in the early stage by using the wavelengths of the wide-band white light spectrum.
Highlights
- Individual use of the thermal measurement according to EN 54-5 in the sensitivity levels 2 to 5 as maximum detector (static –> A1S, A2S) or as rate-of-rise detector with a maximum threshold (differential and static –> A1R, A2R)
- Individual change of detector class for sensitivity levels 2 to 5 using Easy Check 3000
- Pollution detection of the smoke measurement chamber by an additional optical path
- Detector sensitivities are automatically adapted and programmable
- Integrated measurement system and algorithm for condensation recognition (Humitec®)
- Intelligent analysis and suppression mode for the elimination of false alarms (e.g. cigarette smoke)
- Highest reliability by optimal adjustment of the alarm threshold via intelligent algorithm for the fire detection
- Fault monitoring of the measurement chamber signal and Loop 3000 electronics
- Periodic sensor test
- Automatic and manual addressing on Loop 3000
- Integrated isolator and T-branch option
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including dust protection cover for installation phases
SKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 S 1 SE
CONUS – LOOP SOUNDER – RED
Intelligent acoustic signaling device for the Loop 3000 for the external acoustic alarm with bidirectional isolator according to EN 54-3 and EN 54-17.
Highlights
• Activation, monitoring, and supply via Loop 3000-protocol
• Integrated automatic reset function at signal “external signal line on/off” by the fire control panel
• Monitoring of the operating status via Loop 3000
• Independent programming via loop address
• Automatic and manual addressing with Loop 3000
• Integrated Isolator
• 28 different tones, adjustable via DIP-switch including DIN-signal
• Loudness adjustable via DIP-switch
• Functions completely integrated via Loop 3000-protocol
• An aesthetical, robust wall-mounted housing according to IP 41
• Integrated detector base of the PL 3000 seriesSKU: n/a -
Addressable Systems, Fire Alarm, Security Systems
PL 3300 T
THERMAL DETECTOR WITH ISOLATOR
Thermal detector with fixed and rate of rising temperature settings for Loop 3000 with two thermal sensors for earliest fire detection and indication in all environments with difficult ambient conditions and with bidirectional isolator, according to EN 54-5 and EN 54-17
Highlights
- Thermal detector, certified according to EN 54-5 in the temperature classes A1R, A1S (A1) and A2R, A2S (A2), and EN 54-17
- Individual use of the thermal measurement according to EN 54-5 in the sensitivity levels 2 to 5 as maximum detector (static –> A1S, A2S) or as rate-of-rise detector with a maximum threshold (differential and static –> A1R, A2R)
- Individual change of detector class for sensitivity levels 2 to 5 using Easy Check 3000
- Periodic sensor test
- Automatic and manual addressing with Loop 3000
- Integrated Isolator and T-branch option
- Alarm output to control parallel indicator
- Functions completely integrated via Loop 3000 protocol
- Presence and absence switching with selectable sensitivities
- Storage of last maintenance date
- Multicolour LED for alarm (red) and fault (yellow)
- Delivery including protective cover for the installation phase
SKU: n/a